Submersible Pump cable

 

 

 
 

CABLE DESIGN: A submersible Pump cable is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. FAB CABLE is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability

 FEATURE :

Quality backed by 40 years experience in cable industry.

Excellent resistant to moisture, abrasion, grace, oil.

Longer Flex Life

Excellent mechanical & electrical properties.

Generally Conforming to : CENELEC HD 21, IEC 60227,

 

BS 6500, DIN VDE 0281, IS 694.

Approved by GWSSB, GWRDC, TWAD, PHED, PSTC, ONGC,

 

Railways, Mines etc.

Tested by SGS, EIL, RITES, NPC, INTERTEK.

 

APPLICATION :

For continuous use in deep well to supply power to submersible pumps down to depths of 500 mtrs.

Manufacturers and Expoters of 3 core flate cables .

 

FABCON 3CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS)

CONDUCTOR

PVC INSULATION

PVC SHEATH

Conductor Resistance at 20°C (max) ohms/km

Current
Rating at 40°C
Amps.

Nominal 
Area in 

Nos. & Dia.
of wire
  

Nominal 
Thickness

Nominal 
Core Dia.

Nominal 
Thickness

Approx. Overall 
Dimensions

Sq. mm.

Nos. / mm

mm

mm

mm

Thickness
mm

Width 
mm

1.50

22/0.30

0.80

3.25

1.15

6.00

12.80

12.10

14

2.50

36/0.30

0.90

3.84

1.15

6.40

14.60

7.41

18

4.00

56/0.30

1.00

4.50

1.15

7.40

16.80

4.95

26

6.00

85/0.30

1.00

5.30

1.15

7.90

18.70

3.30

31

10.00

140/0.30

1.00

6.50

1.40

9.90

23.70

1.91

42

16.00

226/0.30

1.00

8.00

1.40

11.40

28.00

1.21

57

25.00

354/0.30

1.20

10.10

2.00

14.70

35.50

0.780

72

35.00

495/0.30

1.20

11.30

2.00

16.20

39.50

0.554

90

50.00

703/0.30

1.40

13.60

2.20

18.30

45.50

0.386

115

70.00

440/0.45

1.40

15.30

2.20

20.00

51.00

0.272

143

95.00

475/0.50

1.60

18.00

2.40

23.50

60.00

0.206

165


       Note :

  • The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per Class 5 of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
  • In view of continuous improvements in our design and process, specifications given here in are subject change without notice.

3 Core Flat Cables as per IS 694 : 1990 with ISI mark

CONDUCTOR

PVC INSULATION

PVC SHEATH

Current Rating at 40°C Amps.

Nominal Area
Sq. mm

Nos. Dia Of Wire
Nos./mm

Nominal Thickness

Nominal Thickness

Approx Overall Dimension

mm

mm

Thickness 
mm

Width
mm.

1.5

22/0.30

0.6

0.9

5.20

11.30

14

2.5

36/0.30

0.7

1.0

6.20

13.30

18

4.0

56/0.30

0.8

1.0

7.00

15.60

26

6.0

84/0.30

0.8

1.1

7.40

17.70

31


        Note :

  • The number of wires is approximate and wire diameter is nominal.
  • They shall be so as to satisfy the requirements of conductor resistance as per
    • Class 2 of IS 8130 : 1984 (For 1.5 & 2.5 sq. mm.) &
    • Class 5 of IS 8130 : 1984 (For 4.0 & 6.0 sq. mm.)
 

 

 

spacer